GAO Ballot Package

This page is part of the FHIR Specification (v1.1.0: STU 3 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

This is a frozen snapshot of the FHIR specification created for the purpose of balloting the GAO implementation Guide. It includes draft changes that may be part of the future DSTU 2.1 release but further change is expected. Readers should focus solely on the GAO implementation content, and FHIR DSTU 2 for other purposes.

Uslab\obs-uslab-example4.json

Raw JSON (canonical form)

USLab Ratio Observation Profile Example: Dengue Titer

{
  "resourceType": "Observation",
  "id": "obs-uslab-example4",
  "text": {
    "fhir_comments": [
      "    FHIR build is generating the narratives\n<text>\n\t\t<status value=\"generated\"/>\n\t\t<div xmlns=\"http://www.w3.org/1999/xhtml\">\n\t\t\t<ul>\n\t\t\t\t<li> obs-uslab-example4.xml</li>\n\t\t\t\t<li> id: uslab-example4</li>\n\t\t\t\t<li> Name: USLab Observation Example4</li>\n\t\t\t\t<li>Description: USLab Ratio Observation Profile Canonical Example: Dengue Virus</li>\n\t\t\t</ul>\n\t\t</div>\n\t</text>\n   ",
      "    extension for specimen reject goes here - not for this use case\n\t<extension url=\"http://hl7.org/fhir/StructureDefinition/uslab-specimenrejectreason\">\n\t\t<valueCodeableConcept>\n\t\t\t<coding>\n\t\t\t\t<system value=\"http://hl7.org/fhir/v2/0490\"/>\n\t\t\t\t<code value=\"EX\"/>\n\t\t\t\t<display value=\"Expired\"/>\n\t\t\t</coding>\n\t\t</valueCodeableConcept>\n\t</extension>\n   ",
      "    extension for observation kindt goes here    "
    ],
    "status": "generated",
    "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: obs-uslab-example4</p><p><b>identifier</b>: lab test result ID = 4567 (OFFICIAL)</p><p><b>status</b>: final</p><p><b>code</b>: Dengue IgM Titer <span>(Details : {LOINC code '6812-2' = 'Dengue virus IgM Ab [Titer] in Serum', given as 'Dengue virus IgM Ab [Titer] in Serum'}; {urn:oid:2.16.840.1.113883.3.72.5.24 code 'DGIGM' = '??', given as 'Dengue IgM QN'})</span></p><p><b>subject</b>: <a>Todd Lerr</a></p><p><b>effective</b>: 05/12/2014</p><p><b>issued</b>: 06/12/2014 3:42:15 PM</p><p><b>performer</b>: <a>Dr Leonard T Bloodraw Jr</a></p><p><b>value</b>: 1/256</p><p><b>interpretation</b>: High <span>(Details : {http://hl7.org/fhir/v2/0078 code 'H' = 'High)</span></p><p><b>specimen</b>: <a>Bloo sample</a></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Text</b></td></tr><tr><td>*</td><td>&lt;1:64</td></tr></table></div>"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/uslab-observationkind",
      "valueCode": "result"
    }
  ],
  "identifier": [
    {
      "use": "official",
      "type": {
        "text": "lab test result ID"
      },
      "system": "http://lis.acmelabs.org/identifiers/labtestresult",
      "value": "4567"
    }
  ],
  "status": "final",
  "code": {
    "fhir_comments": [
      "   EH :  The local and /or LOINC test codes go here    "
    ],
    "coding": [
      {
        "fhir_comments": [
          "    EH: LOINC code goes here   ",
          "    EH: LOINC code goes here   "
        ],
        "system": "http://loinc.org",
        "code": "6812-2",
        "display": "Dengue virus IgM Ab [Titer] in Serum"
      },
      {
        "system": "urn:oid:2.16.840.1.113883.3.72.5.24",
        "code": "DGIGM",
        "display": "Dengue IgM QN"
      }
    ],
    "text": "Dengue IgM Titer"
  },
  "subject": {
    "reference": "Patient/patient-uslab-example1",
    "display": "Todd Lerr"
  },
  "effectiveDateTime": "2014-12-05",
  "issued": "2014-12-06T15:42:15-08:00",
  "_issued": {
    "fhir_comments": [
      "    EH: Showing dateTime to ss with TZO although only needed to Day    "
    ]
  },
  "performer": [
    {
      "reference": "Practitioner/pract-uslab-example1",
      "display": "Dr Leonard T Bloodraw Jr"
    }
  ],
  "valueRatio": {
    "fhir_comments": [
      "    In FHIR, units may be represented twice. Once in the\n    agreed human representation, and once in a coded form.\n    Both is best, since it's not always possible to infer\n    one from the other in code.\n\n    When a computable unit is provided, UCUM (http://unitsofmeasure.org)\n    is always preferred, but it doesn't provide notional units (such as\n    \"tablet\"), etc. For these, something else is required (e.g. Snomed-CT)\n      "
    ],
    "numerator": {
      "value": 1
    },
    "denominator": {
      "value": 256
    }
  },
  "interpretation": {
    "fhir_comments": [
      "     eH dataabsent reason  would go here if valueQuantity was empty e.g.:\n\t<dataAbsentReason value=\"error\"/>    "
    ],
    "coding": [
      {
        "system": "http://hl7.org/fhir/v2/0078",
        "code": "H"
      }
    ]
  },
  "specimen": {
    "reference": "Specimen/spec-uslab-example1",
    "display": "Bloo sample"
  },
  "referenceRange": [
    {
      "text": "<1:64"
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.